beautypg.com

Figure 19: chassis and slot ids – Allied Telesis AT-S97 User Manual

Page 124

background image

Chapter 7: Event Log and Syslog Client Commands

124

Chassis and Slot IDs - The chassis ID and slot identifier of the source
module of the message. The first number is the chassis ID number
and the second is the slot number or letter, as shown in Figure 19.

Figure 19. Chassis and Slot IDs

For background information on chassis ID numbers, refer to “Chassis
ID Numbers” on page 18. F
or the slot identifiers, refer to Table 10.

The event messages are listed in Table 11.

Table 10. Slot Identifiers

Identifier

Slot

1, 2, ...

Media converter slot.

A or B

Power supply or fan module slot.

M

Management module slot.

00/2

Chassis ID

Slot Identifier

Table 11. Event Messages

Message

Definition

Classification

Critical Level Messages

Battery Low

The power charge in a module’s battery is
low. The battery may need replacing.

Report

The charge in the module’s battery returned
to normal or the battery was replaced.

Clear

Power Failure

The input voltage of a power supply module
dropped below or exceeded the permitted
operating range.

Report

The input voltage of a power supply module
returned to the proper operating range.

Clear

This manual is related to the following products: