Allied Telesis AT-S97 User Manual
Page 125
AT-S85 and AT-S97 Management Software Command Line Interface User’s Guide
125
Stacking Port Link
A Stack port on the management module or
the AT-MCF2000S Stacking Module
established or lost its link to another Stack
port. (Not supported in version 1.3.0 of the
management software.)
Report
Major Level Messages
Chassis Managership
Acquire
The management module is active.
Report
Chassis Managership
Release
(Not supported in version 1.3.0 of the
management software.)
Report
Chassis Reset
The chassis was reset with the SYSTEM
RESET CHASSIS command.
Report
Cold Boot
A media converter module loaded its boot
loader and management software after
receiving power. It generates this message
when the chassis is powered on or if it is
installed while a unit is powered on.
Report
Fan # Failure
A cooling fan in a power supply or fan
module stopped.
Report
A cooling fan resumed operating after having
stopped.
Clear
High Temperature
Threshold
A module’s operating temperature exceeded
the temperature threshold set with the
SYSTEM SET MODULE command.
Report
A module’s operating temperature returned
below its temperature threshold.
Clear
Module Reset
A media converter module started the
process of initializing its boot loader and
AT-S85 Management Software after it was
reset with the SYSTEM RESET MODULE
command. The completion of the initialization
process is signaled with the Warm Boot
message.
Report
Warm Boot
A media converter module completed the
initialization of its management software after
being reset with the SYSTEM RESET
MODULE command.
Report
Table 11. Event Messages (Continued)
Message
Definition
Classification