CONFIG SHOW
Syntax
config show
Parameters
None
Privilege Levels
Administrator, read-write, and read-only.
Description
This command displays the names of the current and active master
configuration files on the management module. An example is shown in
Figure 31.
Figure 31. CONFIG SHOW Command
The “Last configuration file ran” field displays the name of the master
configuration file used by the management module to configure the
chassis during the last reset or power cycle.
The “Current set configuration file” field displays the name of the active
master configuration file. It is this file that the management module
updates whenever the CONFIG SAVE command is issued. This is also the
file that will be used to configure the chassis during the next reset or power
cycle.
Here is an example of how the process works. Assume the chassis is
currently using a master configuration file called “unit12.cfg,” as illustrated
in Figure 31.
Now assume you decided to configure the settings on the chassis modules
using a different master file called “mcf24.cfg.” If, after specifying the file
as the new active configuration file with the CONFIG SET command, you
were to issue the CONFIG SHOW command, you would see the
information in Figure 32.
Last configuration file ran ............. unit12.cfg
Current set configuration file .......... unit12.cfg (Exists)
Active master configuration file