beautypg.com

Avaya SMON C360 User Manual

Page 43

background image

Avaya C360 Manager User Guide

29

Device Configuration

The following table provides a list of the fields in the Advanced tab of the
Module Configuration dialog box and their descriptions:

Table 3-4. Module Configuration Fields - Advanced Tab

Field

Description

BUPS Module Type

The type of BUPS (BackUp Power Supply)
module in the selected module.

BUPS Module CS

The version of the BUPS (BackUp Power
Supply) module. The version is updated
whenever there is a functional modification to
the module.

Cascading Up Mon.

Determines if the devices in the system are
monitored cascading up. The possible values
are:

Enable - Monitors devices in the

network cascading up. If the connection
is lost, the system reports a error.

Disable - Does not monitor devices in

the network cascading up. If the
connection is lost, the system does not
report a error.

Cascade Down Mon.

Determines if the devices in the system are
monitored cascading down. The possible
values are:

Enable - Monitors devices in the

network cascading down. If the
connection is lost, the system reports a
error.

Disable - Does not monitor devices in

the network cascading down. If the
connection is lost, the system does not
report a error.

Internal PS Status

The operating status of the primary power
supply.

BUPS Status

The operating status of the BUPS.

LLDP Mode

The status of Link Layer Discovery Protocol
(LLDP) Mode on the device:

Enable - Use LLDP Mode.

Disable - Do not use LLDP Mode.

LLDP Tx Interval

The amount of time between packet
transmissions on the device.