Port Redundancy

The following table provides a list of the fields in the Port Redundancy
dialog box and their descriptions:

To configure the device’s port redundancy configuration:

1. Enter an amount in the

Switch Over

field.

2. Select one of the

Switch Back

option buttons.

3. If you selected

After

x

sec

, enter the number of seconds for the

switch back in the

After

x

sec

field.

Table 11-1. Port Redundancy Fields - 802.1x Tab

Field

Description

Name

The name of the port redundancy.

Primary

The primary port of the port redundancy pair.

Secondary

The secondary port of the port redundancy
pair.

Intermodule

If checked, the port redundancy is an
intermodule port redundancy. If not checked,
the port redundancy is not an intermodule
port redundancy.

Switch Over (sec)

The minimum time between switching
between the ports in a port redundancy pair.

Switch Back

The amount of time after the primary port
link is reestablished after which the primary
port takes over from the secondary port.
Possible values include:

Disabled - The primary port does not

take over from the secondary port.

Immediately - The primary port takes

over from the secondary port as soon as
the primary port link is reestablished.

After x sec- The primary port takes over

from the secondary port x seconds after
the primary port link is reestablished.

Redundancy Mode

State of Port Redundancy on the Avaya C360
device. Possible values are:

Enabled - Port Redundancy is enabled

on this device.

Disabled - Port Redundancy is not

enabled on this device.