beautypg.com

NORD Drivesystems BU0300 User Manual

Page 97

background image

7.8 Control terminals

BU 0300 EN

Subject to technical alterations

97

Parameter

Setting value / Description / Note

Supervisor

Parameter set

Available with option

P429

Fixed frequency 1

S P

Always available

-400 ... 400 Hz
[ 0.0 ]

Used to set the fixed frequencies. They are added for multiple selection. If none of the digital inputs
are programmed for enable, the FI is enabled when a fixed frequency is actuated.

P430

Fixed frequency 2

S P

Always available

-400 ... 400 Hz
[ 0.0 ]

See (P429) Fixed frequency 1

P431

Fixed frequency 3

S P

Always available

-400 ... 400 Hz
[ 0.0 ]

See (P429) Fixed frequency 1

P432

Fixed frequency 4

S P

Always available

-400 ... 400 Hz
[ 0.0 ]

See (P429) Fixed frequency 1

P433

Fixed frequency 5

S P

Always available

-400 ... 400 Hz
[ 0 ]

See (P429) Fixed frequency 1