NORD Drivesystems BU0300 User Manual
Page 100
NORDAC trio SK 300E Manual
100
Subject to technical alterations
BU 0300 EN
Parameter
Setting value / Description / Note
Supervisor
Parameter set
Available with option
P480
… -01
Function Bus In Bits
S
… -08
Always available
0 ... 48
[ 0 ]
The Bus I/O In Bits are perceived as digital inputs. They can be set to the same functions (P420...425).
[01] =
Function Bus I/O In Bit 1
[02] =
Function Bus I/O In Bit 2
[03] =
Function Bus I/O In Bit 3
[04] =
Function Bus I/O In Bit 4
[05] =
Function Bus I/O In Bit 5
[06] =
Function Bus I/O In Bit 6
[07] =
Function Bus I/O In Bit 7
[08] =
Function Bus I/O In Bit 8
NOTE
Array parameter:
These parameters can only be set with the ParameterBox, only the Array [01]
can be set with the ControlBox.
The following functions can be set with the Array parameters listed on the previous pages.
Value
Function
Value
Function
0
1
2
3
4
5
6
7
8
9
10
11
12
13
No function
Enable right
Enable left
Phase seq. reversal
Fixed frequency 1
Fixed frequency 2
Fixed frequency 3
Fixed frequency 4
Parameter set switch Bit 0
Maintain frequency (active)
Voltage disable
Quick stop
Fault acknowledgement
PTC resistor input
14
15
16
17
18
19
20
21
22 -29
30
31 -46
47
48
Remote control
Jog frequency
Motor potentiometer
Reserved
Watchdog
Analog setpoint 1 ON/OFF
Analog setpoint 2 ON/OFF
Fixed frequency 5
Reserved
PID controller / process controller
ON/OFF
Reserved
Motorpoti frequency +
Motorpoti frequency -