7.10 Information
BU 0300 EN
Subject to technical alterations
113
Parameter
Setting value / Description / Note
Supervisor
Parameter
set
Available with option
P736
DC Link voltage
S
Always available
0 ... 1000 V DC
Displays the actual link voltage.
P739
Temperature heat sink
S
Always available
0 … XX°C
Displays the actual FI heat sink temperature.
0
= Low range
9999
= High range (20 … 100°C)
P740
... -01
…
... -05
Process data Bus In
S
Always available
0000 ... FFFF
(hex)
This parameter informs
about the actual control word
and the setpoints that are
transferred via the bus
systems.
... -01
= Control word (source from P509)
... -02
= Setpoint 1 (P546)
... -03
= Setpoint 2 (P547)
... -04
= Setpoint 3 (P548)
... -05
= Bus IO In Bits (P480)
P741
... -01
…
... -05
Process data Bus Out
S
Always available
0000...FFFF (hex) This parameter informs
about the actual status word
and the actual values that
are transferred via the bus
systems.
... -01
= Status word
... -02
= Istwert 1 (P543)
... -03
= Actual value 2 (P544)
... -04
= Actual value 3 (P545)
… -05
= Bus IO Out Bits (P481)
P742
Database version
S
Always available
0 ... 9999
Displays the internal database version of the FI.
P743 Inverter
ID
Always available
0.00 ... 250.00 kW Displays the inverter power in kW, e.g. "1.50"
⇒ FI with 1.5 kW nominal power.
P744 Configuration
Always available
0 ... 2
This parameter displays the option modules integrated by the FI.
0 =
No customer unit
1 =
Basic I/O
2 =
Standard I/O
P745 Option
version
S
Always available
0 ... 32767
Design status of the integrated options (only when own processor is present).