2.6

Electrical connection


WARNING

THESE DEVICES MUST BE EARTHED.

Safe operation of the devices presupposes that qualified personnel mount and operate it in
compliance with the instructions provided in these operating instructions.
In particular, the general and regional mounting and safety regulations for work on high voltage
systems (e.g. VDE) must be complied with as must the regulations concerning professional use of
tools and the use of personal protection equipment.
Dangerous voltages can be present at the line input and the motor connection terminals even
when the inverter is switched off. Always use insulated screwdrivers on these terminal fields.
Ensure that the input voltage source is not live before setting up or changing connections to the
unit.

Ensure that the motor is designed for the correct connection current.






2.6.1 Assignments for the adapter unit



Maximum capacity

Supply voltage + 5V

max. 275 mA

Supply voltage + 15V

max. 100 mA

Signal relay

max. 24V / 500 mA

Connection terminal data

Type

Tightening torque

Cable cross-section

Mains connection

Molex 72 / Weko 983

1.1 Nm / 10 Ib-in

2.5 mm

2

/ 20-12 AWG

Controller connections

MFR: Phönix MKDSN 1.5 0.6 Nm / 5.3 Ib-in

1.5 mm

2

/ 30-14 AWG

Motor connection
Mechanical brake
Brake resistor

Phönix GMKDS 3

0.6 Nm / 5.3 Ib-in

1.5 mm

2

/ 30-12 AWG

Cable connections

M12 - M16 - M20 - M25

2.5 - 6 - 8.5 - 10Nm