beautypg.com

NORD Drivesystems BU0300 User Manual

Page 123

background image

8 Fault messages

BU 0300 EN

Subject to technical alterations

123

Display

in the ControlBox

Error

text in the Parameter Box

Cause

Remedy

Group

Detail in
P700 / P701

E019

19.0

Parameter identification error

Automatic identification of the connected motor was
unsuccessful

Check motor connections

Check pre-set motor data (P201 ... P209)

19.1

Motor star/delta circuit is not
correct

E020

20.0

reserved

System error in program execution, triggered by EMC
interference.
Please comply with wiring guidelines in Chap. 2.5 .
Use additional external mains filter. (Chap. 9.5 EMC)
FI must be very well "earthed".

20.1 Watchdog

20.2 Stack

Overflow

20.3 Stack

Underflow

20.4 Undefined

Opcode

20.5 Protected

Instruction

20.6 Illegal

Word

Access

20.7 Illegal

Instruction

Access

20.8 EEPROM

error

20.9

Reserved

21.0

NMI

error

(not used by hardware)

21.1 PLL

Error

21.2 ADU

Overrun

21.3 PMI

Access Error