Screen layout during parameterisation
If the setting of a parameter is changed, the value flashes until it is confirmed with the ENTER key (
). To
load the factory setting of the parameter to be edited, both VALUE keys (
and
) must be pressed
together. To store this change, the setting must also be confirmed with the ENTER key.
If the change is not to be stored, then pressing one of the SELECTION keys (
or
) will call up the
previously stored value and pressing a SELECTION key again will exit the parameter.
P102
PS1
3
Start-up time
2,90 s
ONLINE
U1 P1
E BLOCK
Actual parameter to be
edited (No.)
Menu
structure level
Actual parameter
data set to be edited
Actual parameter to be
edited (Text)
Current
ParameterBox
status
Selected frequency
inverter
Active parameter data set
in control medium
Status of the
frequency inverter
Actual parameter
value
Note:
The display in the lower line is used to display the actual status of the ParameterBox and the
frequency inverter being controlled.