3.2 Technology unit overview

BU 0300 EN

Subject to technical alterations

35

3.2.1 Mounting the technology unit

The mounting of the technology unit must be implemented as follows:

1. Switch off the mains voltage, observe the waiting period.
2. Undo the 6 fastening screws on the blind plate and remove the blind plate (see Fig. 1 on next page).
3. Attach the PE connection on the inside of the technology unit being mounted (see Fig. 2 on next page).

Fit the seal together with the technology unit on the surface of the frequency inverter. Ensure that the
multipoint connector has full contact.

4. Lightly tighten all 6 fastening screws.
5. Now tighten the 6 fastening screws in the specified sequence from 1 to 6 (see Fig. 1 on next page) and

with the torque given in the table.



Frequency inverter size

Screw size

Tightening torque

Size 1

M4 x 8

1.5Nm ± 20%

Size 2

Fig. 1: Technology unit fastening screws

Fig. 2: PE connection on the technology unit

Screw 3

Screw 4

Screw 6

Screw 2

Screw 1

Screw 5

ATTENTION

Operation is not permitted if there is no secure PE connection to the frequency inverter and to the
technology unit!