background image

4.5 Parameters of the ParameterBox

BU 0300 EN

Subject to technical alterations

65

Menu group < Options> (P13xx)

Parameter

Setting value / Description / Note

P1301

Language

Selection of languages for operation of the ParameterBox

Available languages

: German English French

Spanish

Swedish

Dutch

P1302

Operating mode

Selection of the operating mode for the ParameterBox

Offline:

The ParameterBox is operated autonomously. No PC or frequency inverter is
connected. The parameter data set of the frequency inverter is not accessed. The
storage objects of the ParameterBox can be parameterised and administrated.

Online:

A frequency inverter is located at the interface of the ParameterBox. The frequency
inverter can be parameterised and controlled. When changing to the "ONLINE"
operating mode, a bus scan is started automatically.

PC slave:

A PC is located at the interface of the ParameterBox. The ParameterBox can be
addressed as a slave by the NORD CON software. The storage objects log on as
separate frequency inverters

S1 Ö USS address 1
S2 Ö USS address 2
S3 Ö USS address 3
S4 Ö USS address 4
S5 Ö USS address 5

P1303

Automatic bus scan

Setting the switch-on characteristics.

Off

An automatic bus scan is not implemented. The frequency inverters connected
before switching off must be looked for again after switch-on.

On

A bus scan is automatically implemented when the ParameterBox is switched on.

P1304

Contrast

Contrast setting of the ParameterBox display
Value range: 0% ... 100%; Resolution 1%

P1305

Set password

The user can set up a password in this parameter.
If a value other than 0 has been entered in this parameter, then the settings of the ParameterBox
or the parameters of the connected frequency inverter cannot be altered.

P1306

Box password

If the password function is to be reset, the password selected in the >Set Password< parameter
must be entered here. If the correct password has been selected, than all functions of the
ParameterBox can be used again.

P1307

Reset Box
parameter

In this parameter the ParameterBox can be reset to the factory setting. All ParameterBox settings
and the data in the storage media will be deleted.

P1308

Software version

Displays the software version of the ParameterBox. Please note for future use.