Motor 3 – NORD Drivesystems BU0300 User Manual
Page 23
2 Assembly and installation
BU 0300 EN
Subject to technical alterations
23
Control connections:
[21]
Dig. Input 1
(PTC input) (*)
[41]
+
5V
supply
voltage
[40]
0V,
GND
[41]
+
5V
supply
voltage
[40]
0V, GND
[42]
+ 15V supply voltage
[74]
RS 485 interface: B (-)
[73]
RS 485 interface: A (+)
Termination resistor RS 485 On/Off
[02]
Signal relay (error)
[01]
Signal relay
[…]
= Terminal No.
-B +B
-Br +Br
U V W
L1 L2 L3
Option
Customer unit
Earth "PE"
(connection of mains line)
System connector M12 socket
Mains voltage:
3~ 400V / 3~ 230V
1
) 1~ 230V, 0,37-0,75kW
2
) 1~ 230V, 1,1kW
Mains fuse:
See Chap. 8 "Technical data"
Mechanical brake
See Chap. 2.6.4
"Electromechanical brake"
External brake resistor
The polarity can be ignored.
Earth "PE"
(Additional PE terminal, e.g. for
control line, braking resistor)
Motor
3~
(*) The digital inputs can be connected
with the internal 15 V or from the PLC
(7.5 – 33V DC). The data in "(...)"
represent the factory settings.
PE- socket = 3~ 400V device
PE- connector = 3~ 230V device
PE
L1 L2 L3
1
( PE
L
N
- )
2
( PE
-
N
L )