2.3
Installation
An adapter unit with the correct connection terminals and appropriate plug-in connections for the frequency
inverter is always required for the SK 300E. There are two types of adapter unit, the SK TI 0/1 (-C) and SK TI
0/2 (-C), and their different properties are described in the following chapters.
The adapter units are both suitable for the inverter sizes 1 and 2.
2.3.1 Adapter unit SK TI 0/1
(SK TI 0/1, Part. No. 275115010)
(SK TI 0/1-C, Part. No. 275175010)
The adapter units SK TI 0/1 and SK TI 0/1-C are cast enclosures which are fitted with different sizes of cable
glands on both sides. They are fully fitted with blind plugs.
The following are available:
3 screw connections M12 (e.g. brake cable), 2 connections in the SK TI 0/1-C
4 screw connections M20 (e.g. supply voltage)
1 screw connection M16 (for connection socket M12 of the ParameterBox SK PAR-2H)
Components of the adapter unit TI 0/1:
Cable for motor
U-V-W connection
M12 socket
Cable for motor PTC
Screw accessories
Cast enclosure
CIU - customer interface unit
ATTENTION
The adapter unit SK TI 0/1 is available for the protection class IP55 and the adapter unit SK TI
0/1-C for IP66. Otherwise, the functionality and dimensions of both adapter units are identical.
However special measures (see Chap. 1.7) are implemented in the IP66 version to maintain this
protection class.