4.7 Data transfer with NORD CON
BU 0300 EN
Subject to technical alterations
69
4.7
Data transfer with NORD CON
The NORDAC ParameterBox S1 to S5 storage elements can be administrated and archived using the NORD CON
control and parameter software.
To achieve transfer of data, the PC serial interface (RS232) must be connected to the ParameterBox via an
interface converter (SK IC1-232/485, Part. No. 276970020) and suitable connection cable. (M12 Socket/SUB-
D, Part. No. 278910210). In addition, the interface inverter must be connected to an external supply voltage.
Use the USB/5V adapter for this, it is connected to the interface converter via a cinch connector and to the
PC/laptop via a USB connector.
The following components are required for the ParameterBox
Æ PC/laptop connection:
5V- USB port
adapter
PC / laptop
ParameterBox
SK PAR-2H
Mat.No. 278910100
Adapter M12 SO/SUB-D
for SK PAR-2H Æ SK IC1
Mat.No. 278910210
Interface converter
SK IC1-232/485
Mat.No. 276970020
Software
NORD CON
Mat.No. 6099985
(NORD PAC)
Adapter USB/5V for
SK IC1-232/485
Mat.No. 278910220
RS232
In this set-up, communication is controlled by the PC. For this, the ParameterBox must be set in the menu
group >Options<, Parameter >Operating mode< (P1302) to the value PC slave. After a bus scan, the NORD
CON
program will then detect the filed storage objects S1 to S5 as separate frequency inverters with bus
addresses 1 to 5 and display them onscreen.
NOTE
Only frequency inverter parameter data sets already saved in the storage objects can be detected and
edited by the NORD CON parameterisation software.
To edit the data set of a new frequency inverter, the inverter type first has to be set via the >Load factory
settings (P1204)<
parameter. The NORD CON software then detects the new storage object in a new
bus scan. The new parameter data set can then be edited with the usual tools.
All NORD CON parameterisation
functions are now available.