beautypg.com

NORD Drivesystems BU0300 User Manual

Page 126

background image

NORDAC trio SK 300E Manual

126

Subject to technical alterations

BU 0300 EN

9.2

Electrical data 230V

Size 1

Device type:

SK 300E ...

-370-323-B(-C)

-550-323-B(-C)

-750-323-B(-C)

Material number

…-B 275120370

275120550

275120750

…-B-C 275160370

275160550

275160750

Nominal motor power
(4-pole standard motor)

230V

0.37 kW

0.55 kW

0.75 kW

240V

0.5 hp

0.75 hp

1 hp

Mains phases

1

1/3

AC

Mains voltage

200-240 V, ±10 %, 47 ... 63 Hz

Output voltage

3 AC 0 - Mains voltage

Rated output current (230V) rms

[A]

2.2

3.0

4.0

Rated input current

1

(230V) rms

[A]

5.0/3.1 7.2/4.2 9.7/5.6

Recom. mains fuse

1

(230V)

Slow-

blowing [A]

16/10 16/10 16/10

Ventilation type

Free convection

Weight Approx.

[kg]

4.0



Size 2

Device type:

SK 300E ...

-111-323-B(-C)

-150-323-B(-C)

-221-323-B(-C)

Material number

…-B

275121100 275121500 275122200

…-B-C

275161100 275161500 275162200

Nominal motor power
(4-pole standard motor)

230V

1.1 kW

1.5 kW

2.2 kW

240V 1½

hp

1

2 hp

3 hp

Mains phases

2

1/3 AC

3 AC

Mains voltage

200-240 V, ±10 %, 47 ... 63 Hz

Output voltage

3 AC 0 - Mains voltage

Rated output current (230V))

rms

[A]

5.5 7.0 9.5

Rated input current

2

(230V) rms

[A]

13.1/7.7

9.8

13.3

Recom. mains fuse

2

(230V)

Slow-

blowing [A]

20/16 16 20

Ventilation type

Free convection

Weight Approx.

[kg]

8.4

1

Single phase / three phase operation