NORD Drivesystems BU0300 User Manual
Page 126
NORDAC trio SK 300E Manual
126
Subject to technical alterations
BU 0300 EN
9.2
Electrical data 230V
Size 1
Device type:
SK 300E ...
-370-323-B(-C)
-550-323-B(-C)
-750-323-B(-C)
Material number
…-B 275120370
275120550
275120750
…-B-C 275160370
275160550
275160750
Nominal motor power
(4-pole standard motor)
230V
0.37 kW
0.55 kW
0.75 kW
240V
0.5 hp
0.75 hp
1 hp
Mains phases
1
1/3
AC
Mains voltage
200-240 V, ±10 %, 47 ... 63 Hz
Output voltage
3 AC 0 - Mains voltage
Rated output current (230V) rms
[A]
2.2
3.0
4.0
Rated input current
1
(230V) rms
[A]
5.0/3.1 7.2/4.2 9.7/5.6
Recom. mains fuse
1
(230V)
Slow-
blowing [A]
16/10 16/10 16/10
Ventilation type
Free convection
Weight Approx.
[kg]
4.0
Size 2
Device type:
SK 300E ...
-111-323-B(-C)
-150-323-B(-C)
-221-323-B(-C)
Material number
…-B
275121100 275121500 275122200
…-B-C
275161100 275161500 275162200
Nominal motor power
(4-pole standard motor)
230V
1.1 kW
1.5 kW
2.2 kW
240V 1½
hp
1
2 hp
3 hp
Mains phases
2
1/3 AC
3 AC
Mains voltage
200-240 V, ±10 %, 47 ... 63 Hz
Output voltage
3 AC 0 - Mains voltage
Rated output current (230V))
rms
[A]
5.5 7.0 9.5
Rated input current
2
(230V) rms
[A]
13.1/7.7
9.8
13.3
Recom. mains fuse
2
(230V)
Slow-
blowing [A]
20/16 16 20
Ventilation type
Free convection
Weight Approx.
[kg]
8.4
1