Page 44

background image

3 4

X-S

CALE

/ X2 C

ONFIGURATION

M

ANUAL

T

EST

D

ISPENSE

A

CCESS

I

NSTRUCTIONS

:

1.

From the D

IAGNOSTICS

screen, select the D

ISPENSER

option by pressing <4> on the keypad.

2.

From the D

ISPENSER

screen, select the T

EST

D

ISPENSE

option by pressing <3> on the keypad.

D

ESCRIPTION

:

The T

EST

D

ISPENSE

command allows the user to dispense note(s) from each installed and operational cassette

into the reject cassette. This test exercises the dispenser mechanism without sending notes to the exit. The
Test Dispense can only be exercised on the cassettes installed.

Once the cassette information is retrieved, the user will be prompted to enter the number of note(s) to be
dispensed from cassette A through D, if applicable. The values for the number of notes are 1 to 5. If the user
enters a number greater than 5, it will automatically default to 5.

Press the number on the keypad for the cassette(s) and enter the desired value. Press

NTER

>. Repeat for

the remaining cassettes that are available.

Next, press the

NTER

> key to perform the test. The dispenser will dispense the note(s) from the cassette(s)

into the reject cassette, compartment, or reject vault, if applicable.

When the test is completed, the user will be prompted that test was completed successfully.

Shutter Test

The S

HUTTER

T

EST

exercises the unit’s shutter assembly (Open/Close). This function will be available for

FT5000 units. Caution: Take care not to insert any objects or fingers when assembly is opening/closing.