X2 c – Triton X-SCALE/X2 Configuration Manual User Manual
Page 44
3 4
X-S
CALE
/ X2 C
ONFIGURATION
M
ANUAL
T
EST
D
ISPENSE
A
CCESS
I
NSTRUCTIONS
:
1.
From the D
IAGNOSTICS
screen, select the D
ISPENSER
option by pressing <4> on the keypad.
2.
From the D
ISPENSER
screen, select the T
EST
D
ISPENSE
option by pressing <3> on the keypad.
D
ESCRIPTION
:
The T
EST
D
ISPENSE
command allows the user to dispense note(s) from each installed and operational cassette
into the reject cassette. This test exercises the dispenser mechanism without sending notes to the exit. The
Test Dispense can only be exercised on the cassettes installed.
Once the cassette information is retrieved, the user will be prompted to enter the number of note(s) to be
dispensed from cassette A through D, if applicable. The values for the number of notes are 1 to 5. If the user
enters a number greater than 5, it will automatically default to 5.
Press the number on the keypad for the cassette(s) and enter the desired value. Press
NTER
>. Repeat for
the remaining cassettes that are available.
Next, press the
NTER
> key to perform the test. The dispenser will dispense the note(s) from the cassette(s)
into the reject cassette, compartment, or reject vault, if applicable.
When the test is completed, the user will be prompted that test was completed successfully.
Shutter Test
The S
HUTTER
T
EST
exercises the unit’s shutter assembly (Open/Close). This function will be available for
FT5000 units. Caution: Take care not to insert any objects or fingers when assembly is opening/closing.