Host Receipt – 2 ASCII numbers followed by a variable amount of ASCII data to be displayed
exactly as formatted by the host. T
1
T
2
(T
3
)
2 Numeric (T
1
T
2
) – 2 ASCII numbers representing the character set selection. Currently ‘00’
will always be sent indicating the default character set should be used.
Variable Length ASCII (T
3
) – Formatted ASCII text that will be printed exactly as it is sent
from the host.
Misc FID ‘uk’:
Printer Capabilities- 10 ASCII numbers representing the current configuration of the terminal
printer. T
1
T
2
T
3
T
4
T
5
T
6
T
7
T
8
T
9
T
10
1 Numeric (T
1
) – Represents the current printer mode ‘1’ – Graphic ‘2’– Text.
3 Numeric (T
2
T
3
T
4
) – This field is reserved for future use, but it will initially contain ‘000’.
2 Numeric (T
5
T
6
) – The maximum number of characters per line.
2 Numeric (T
7
T
8
) – The maximum number of lines per statement.
2 Numeric (T
9
T
10
) – The default character set that is used by the system. ‘00’ will be sent
indicating the system default. Future enhancements may specify other character sets.
Note: The ‘uk’ FID will always be sent from the terminal in a configuration download
request.
Default Parameters
The default values for new features are as follows:
•
Archive Unaudited Records: Disabled
•
Bill Mix Method: Minimize
•
Journal Data in Host Response: Disabled
Known Issues
Journal Upload Enable/Disable from Management
If a download keys is initiated from Management Functions (Key Management=>Download
Keys), the flag in the message response to enable/disable is ignored. This feature will only be
enabled or disabled during a transaction request.
X2 2.0.1 Software Release Notes
Triton Systems
Page 18 of 19