Corrected 188/190 error reporting, Permanent tcp connection, Space-filled phone numbers – Triton X-SCALE/X2 Configuration Manual User Manual
Page 311: Reloading paper, Extended amounts, Software error followed a, Card reader error, Orrected, Rror, Eporting

561 software error followed a 196 card reader error
561 Software errors was masking the true error that was an 196 (Card Reader error). This
release checks for the 196 error before setting the 561 error.
Corrected 188/190 Error Reporting
This version of software will correctly report a 188 (Communications Key Not Configured)/ 190
(Master Key Not Configured) error.
Permanent TCP Connection
The socket for permanent connection would block from receiving data if the host did not respond
to a request within the specified Timeout setting. Now the terminal will detect this condition and
rebuild the socket when this occurs.
Space-filled phone numbers
This release will no longer validate a space filled number for dialing. If this is encountered the
number will not be attempted.
Reloading Paper
This release does not require the terminal owner to go into diagnostics and reset the printer when
reloading paper. If the terminal is configured to be in service with printer errors and an out of
paper event occurs, the terminal will reset the printer automatically when paper is reloaded.
Extended Amounts
The extended amounts option has been moved to Management => Terminal Configuration =>
Communication dialog as the "Amount Type" option. This configuration consists of the
following options:
o Standard (No change from current software)
o Extended Amounts (No change from current software)
o Full Extended Amounts (Not currently supported in the South Africa screen file)
Software Release Notes
Triton Systems
Page 7 of 30
July 26, 2007