Description of Changes

TDM-1XX Mechanisms Configurations are reporting as TDM-2XX

This release corrects the problem of newer TDM firmware that responds to both command

protocols of the TDM product line. These command protocols affects the way that cassettes are

managed and error codes that are reported. This release will test for a single cassette TDM

before testing for a TDM multi-cassette mechanism. With this and future versions software,

when installing an update file over any prior software release on a terminal with a

TDM100 or TDM150 dispenser, the cassette multiple amount may need to be reconfigured

before the terminal will go into service **.

** Note - that in this situation, if an update file is loaded from Triton Connect, the machine

can only be put into service by configuring the cassette multiple amount in Management

Functions at the terminal. Subsequent update loads will not require this step.

Recording NAKs from the Dispenser

When the dispenser sends a NAK(0x15) during a dispense the terminal will record this in the

journal as an 130 not an 371.

Lost EOT errors

The dispenser protocol ends with an EOT (0x04) being sent to the terminal from the dispenser.

The terminal will no longer report an error when this character is not received.

TDM Click Count History Report

This release corrects the reporting of the click count history report by correctly indexing all of

the click counts from the dispenser, which is available in the diagnostic menu of the terminal.

Also, this release corrected the retrieval of the Sequence numbers of the click count history

report.

Removed the Learn from the Reset Dispenser

This release removes the relearn command from the Reset Dispenser option in the diagnostic

menu.

Uses Generic Reference for all TDM Dispensers

All terminals that are equipped with TDM’s will now either see “TDM Single Cassette" or

"TDM Multi-Cassette" as the dispenser type. If the dispenser only has one feed channel the

terminal will report it as a “TDM Single Cassette”. If the dispenser has more than one feed

channel the terminal will report the dispenser as a “TDM Multi-Cassette”.

Journal Record Dispense Status Records the Full Value

This release correctly stores the Dispense Status in the journal record. This release no longer