Software Release Notes
Triton Systems
Page 4 of 16
January 10, 2007
Description of Changes
TDM-1XX Mechanisms Configurations are reporting as TDM-2XX
This release corrects the problem of newer TDM firmware that responds to both command
protocols of the TDM product line. These command protocols affects the way that cassettes are
managed and error codes that are reported. This release will test for a single cassette TDM
before testing for a TDM multi-cassette mechanism. With this and future versions software,
when installing an update file over any prior software release on a terminal with a
TDM100 or TDM150 dispenser, the cassette multiple amount may need to be reconfigured
before the terminal will go into service **.
** Note - that in this situation, if an update file is loaded from Triton Connect, the machine
can only be put into service by configuring the cassette multiple amount in Management
Functions at the terminal. Subsequent update loads will not require this step.
Recording NAKs from the Dispenser
When the dispenser sends a NAK(0x15) during a dispense the terminal will record this in the
journal as an 130 not an 371.
Lost EOT errors
The dispenser protocol ends with an EOT (0x04) being sent to the terminal from the dispenser.
The terminal will no longer report an error when this character is not received.
TDM Click Count History Report
This release corrects the reporting of the click count history report by correctly indexing all of
the click counts from the dispenser, which is available in the diagnostic menu of the terminal.
Also, this release corrected the retrieval of the Sequence numbers of the click count history
report.
Removed the Learn from the Reset Dispenser
This release removes the relearn command from the Reset Dispenser option in the diagnostic
menu.
Uses Generic Reference for all TDM Dispensers
All terminals that are equipped with TDM’s will now either see “TDM Single Cassette" or
"TDM Multi-Cassette" as the dispenser type. If the dispenser only has one feed channel the
terminal will report it as a “TDM Single Cassette”. If the dispenser has more than one feed
channel the terminal will report the dispenser as a “TDM Multi-Cassette”.
Journal Record Dispense Status Records the Full Value
This release correctly stores the Dispense Status in the journal record. This release no longer