23-12 XL-BASIC Programming Guide

XL™ SERIES

--- Com Port Commands —

OPENCOM1

Turn on the RS232 drivers for com port 1, initialize I/O buffers
making it available for the ‘print’ and ‘input’ commands.

CLOSECOM1

Turn off the RS232 drivers for com port 1.

FLUSHCOM1

Clear out the input buffer for Com 1.

OPENCOM2

Turn on the RS232 drivers for com port 2 and enable it to work
with the print2 command.

CLOSECOM2

Turn off the RS232 drivers for com port 2.

FLUSHCOM2

Clear out the input buffer for Com 2.

OPENCOM3

Turn on the RS232 drivers for com port 3 and enable it to work
with the print3 command.

CLOSECOM3

Turn off the RS232 drivers for com port 3.

FLUSHCOM3

Clear out the input buffer for Com 3.

PRINT

Print text or data to the standard output which is com port 1. Any text listed
between quotes will be sent directly to the serial port.

Example:

print “this is a test”

This sends the test message out the serial port and terminates the message with a
carriage return and a line feed. To suppress the carriage return and line feed use a
comma ‘,’ at the end of the message.

Example:

print “this is a test”,

Data may also be printed on the same line using the comma ‘,’or the semicolon ‘;’
as follows:

Example:

print “stage = “,stage

rem line 1

print “stage = “,stage,” temp = “,PtTemp

rem line 2

print “stage = “;stage,” temp = “,PtTemp,

rem line 3

The first line is terminated with the carriage return line feed. This is because there
is no comma or semicolon formatting character after the variable stage.
In the second example the two data values are separate based on the spaces inside

This manual is related to the following products: