beautypg.com

Ac characteristics: jtag test port interface – Rainbow Electronics DS31256 User Manual

Page 175

background image

DS31256

175 of 181

AC CHARACTERISTICS: JTAG TEST PORT INTERFACE

(V

DD

= 3.0V to 3.6V, T

A

= 0°C to +70°C.)

PARAMETER SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

JTCLK Clock Period

t1

1000

ns

JTCLK Clock Low Time

t2

400

ns

JTCLK Clock High Time

t3

400

ns

JTMS/JTDI Setup Time to the Rising
Edge of JTCLK

t4

50 ns

JTMS/JTDI Hold Time from the Rising
Edge of JTCLK

t5

50 ns

Delay Time from the Falling Edge of
JTCLK to Data Valid on JTDO

t6

2 50 ns

Figure 13-6. JTAG Test Port Interface AC Timing Diagram


JTCLK

JTMS/JTDI

JTDO

t4

t5

t6

t1

t2

t3