# execution of each script.

# Note: The HALT_SCRIPT_TIMEOUT should be greater than the sum

of

# all SERVICE_HALT_TIMEOUT specified for all services.

RUN_SCRIPT /etc/cmcluster/ob2cl/ob2cl.cntl

RUN_SCRIPT_TIMEOUT NO_TIMEOUT

HALT_SCRIPT /etc/cmcluster/ob2cl/ob2cl.cntl

HALT_SCRIPT_TIMEOUT NO_TIMEOUT

# Enter the SERVICE_NAME, the SERVICE_FAIL_FAST_ENABLED and the

# SERVICE_HALT_TIMEOUT values for this package. Repeat these

# three lines as necessary for additional service names. All

# service names MUST correspond to the service names used by

# cmrunserv and cmhaltserv commands in the run and halt

scripts.

#

# The value for SERVICE_FAIL_FAST_ENABLED can be either YES or

# NO. If set to YES, in the event of a service failure, the

# cluster software will halt the node on which the service is

# running. If SERVICE_FAIL_FAST_ENABLED is not specified, the

# default will be NO.

#

# SERVICE_HALT_TIMEOUT is represented in the number of seconds.

# This timeout is used to determine the length of time (in

# seconds) the cluster software will wait for the service to

# halt before a SIGKILL signal is sent to force the termination

# of the service. In the event of a service halt, the cluster

# software will first send a SIGTERM signal to terminate the

# service. If the service does not halt, after waiting for the