Integrations with Other Applications

MC/ServiceGuard Integration

Chapter 13

635

SERVICE_NAME

,

SERVICE_FAIL_FAST_ENABLED

,

SERVICE_HALT_TIMEOUT

Enter the service information. For the service name, you can enter
any name but note that you will use the same name in the control
file afterwards. For example:

SERVICE_NAME omni_sv

SEVICE_FAIL_FAST_ENABLED NO

SERVICE_HALT_TIMEOUT 300

SUBNET

Enter the subnet of the cluster. For example:

SUBNET 10.17.0.0

8. Modify the Data Protector package control file (for example,

/etc/cmcluster/ob2cl/ob2cl.cntl

). Refer to the example of this

file in “Example of the Package Control File” on page A-38.

In this file, modify the following fields:

Modifying the
Control File

VG [n]

Specify the volume group used by this package. For example:

VG [0] = /dev/vg_ob2cm

LV [n]

,

FS [n]

,

FS_MOUNT_OPT [n]

Specify the logical volume and filesystem mount information:

LV [0] = /dev/vg_ob2cm/lv_ob2cm

FS [0] = /omni_shared

FS_MOUNT_OPT[0]=” ”

IP

,

SUBNET

Specify the IP and the subnet information used by this package.
For example:

IP [0] = 10.17.3.230

SUBNET [0] = 10.17.0.0

SERVICE_NAME

,

SERVICE_CMD

,

SERVICE_RESTART

Specify the service name, command, and restart parameters.