Integrations with Other Applications

MC/ServiceGuard Integration

Chapter 13

633

/opt/omni/sbin/install/omniforsg.ksh -secondary

/omni_shared

5. Unmount the mount point directory (Data Protector shared

directory):

umount /omni_shared

6. Deactivate the volume group you imported:

vgchange -a n /dev/vg_ob2cm

Configuring the Cell Manager Package

NOTE

The following section provides step-by-step examples to configure the
Data Protector package. Directory and file names, numbers, and other
variables will differ from the following examples according to your
environment. The cluster configuration file name

cluster.conf

and the

Data Protector package name

ob2cl

is used also as an example. You

should follow the names given to you by your network or domain
administrator.

Note that the Data Protector daemons are not running anymore on
either cluster node.

Prerequisites

• The Data Protector Cell Manager should be installed and configured

on both cluster nodes as explained in the previous section.

• Before configuring the Data Protector cluster package, you should

have a cluster configuration file created and edited.

Configuring Data
Protector Package

On the Primary Cell Manager node proceed as follows:

1. Check the cluster configuration file for errors:

cmcheckconf -C /etc/cmcluster/cluster.conf

If there are errors, fix them.

If there are no errors, enable the configuration:

cmapplyconf -C /etc/cmcluster/cluster.conf

2. Start the cluster:

cmruncl