HP B6960-90078 User Manual
Page 443

Managing the Data Protector Internal Database
Maintaining the IDB
Chapter 9
413
On Windows systems:
to
On UNIX systems:
/var/opt/omni/db40/msg
to
/var/opt/omni/db40/msg
• SIBF files to the same relative pathname:
On Windows systems:
to
On UNIX systems:
/var/opt/omni/db40/meta
to
/var/opt/omni/db40/meta
• DC directories to the same or other locations. You can get the list
of DC directories using the
omnidbutil -list_dcdir
command.
3. Start Data Protector services on the target system using the
omnisv
-start
command:
• On Windows:
• On UNIX:
/opt/omni/sbin/omnisv -start
If the IDB is installed on MC/ServiceGuard, run the
cmrunpkg
command on the active node to start the Data Protector
package.
If the IDB is installed on Microsoft Cluster Server, bring the
OBVS_VELOCIS
and
OBVS_MCRS
cluster groups online using the
Cluster Administrator utility.
4. Run the
omnidbutil -change_cell_name
command.
5. Relocate DC directories on the target system.
6. Run the
omnidbutil -remap_dcdir
command for Data Protector to
refresh the new locations of the DC directories.