beautypg.com

The cell manager crashes during the core upgrade, The core upgrade runs out of disk space – HP B6960-90078 User Manual

Page 623

background image

Troubleshooting

Troubleshooting the IDB

Chapter 12

593

Upgrade of detail part running.

The detail upgrade was started and is currently running.

Upgrade of detail part finished.

The detail upgrade finished.

The Cell Manager crashes during the core upgrade

The following methods can help you to identify the problem:

• The

omnidbutil –upgrade_info

command on the Cell Manager

reports

Core upgrade failed.

• The

upgrade.log

file on the Cell Manager contains the

UCP session

started

entry but does not contain either the

UCP session

finished

nor the

Session was aborted (Upgrade core part)

entry.

Action

1. Run

/opt/omni/sbin/omnisv -status

to check whether the Data

Protector services are running on the Cell Manager. If they are not
running, start them using the

/opt/omni/sbin/omnisv - start

command.

2. Run the

omnidbinit

command on the Cell Manager to initialize the

new database. The A.03.51 IDB is set to read-only mode and is
therefore left intact.

3. Run the

omnidbupgrade -ucp

command to restart the core upgrade.

4. When the core upgrade is finished, continue with the detail part

upgrade.

The core upgrade runs out of disk space

The

upgrade.log

file on the Cell Manager contains the

Not enough

disk space

or

not enough configure extension/binary files to

perform upgrade entry

after the

UCP session started

entry. Refer to

the HP OpenView Storage Data Protector Software Release Notes for disk
space requirements.

Action

1. Free up disk space on the system where the IDB is installed.

2. Run the

omnidbinit

command to initialize the new database. The

A.03.51 IDB is set to read-only mode and is therefore left intact.

3. Restart the core upgrade using the

omnidbupgrade –ucp

command.