The dc binary files are corrupted or missing, Performance problems – HP B6960-90078 User Manual
Page 629

Troubleshooting
Troubleshooting the IDB
Chapter 12
599
• On UNIX, the Data Protector MMD (
/opt/omni/lbin/mmd
) is not
displayed when listing the Data Protector processes using the
ps -ef
| grep omni
command.
On Windows, the Data Protector MMD process (
mmd.exe
) is not listed
among processes in the Windows Task Manager.
Action
1. Close the Data Protector GUI.
2. Run the
omnisv –stop
command to stop the Data Protector
services/processes.
3. Run the
omnisv –start
command to start the Data Protector
services/processes.
4. Run the
omnisv –status
command to check if all the
services/processes are running.
The DC binary files are corrupted or missing
If the DC binary files are corrupted or missing, the error message
Open
of Detail Catalog Binary File failed
is displayed when browsing
backed up objects in the
Restore
context.
• The
omnidbcheck -bf
command reports that one or several DC
binary files are missing or of incorrect size, or the
omnidbcheck -dc
command reports that one or several DC binary files are corrupted.
• The
debug.log
file on the Cell Manager, located in the
(Windows systems) or
in the
/var/opt/omni/log/debug.log
(UNIX systems) contains
one or several entries on Data Protector not being able to open a DC
binary file.
Action
Recreate DC binary files by importing catalog from media. For more
information refer to “Handling Minor Database Corruption in the DCBF
Part” on page 422.
Performance Problems
The number of IDB objects and IDB objects' sizes are too large
When browsing object versions and single files for restore, it can take a
long time before the information is read from the IDB and displayed.