The dc binary files are corrupted or missing, Performance problems – HP B6960-90078 User Manual

Page 629

background image

Troubleshooting

Troubleshooting the IDB

Chapter 12

599

• On UNIX, the Data Protector MMD (

/opt/omni/lbin/mmd

) is not

displayed when listing the Data Protector processes using the

ps -ef

| grep omni

command.

On Windows, the Data Protector MMD process (

mmd.exe

) is not listed

among processes in the Windows Task Manager.

Action

1. Close the Data Protector GUI.

2. Run the

omnisv –stop

command to stop the Data Protector

services/processes.

3. Run the

omnisv –start

command to start the Data Protector

services/processes.

4. Run the

omnisv –status

command to check if all the

services/processes are running.

The DC binary files are corrupted or missing

If the DC binary files are corrupted or missing, the error message

Open

of Detail Catalog Binary File failed

is displayed when browsing

backed up objects in the

Restore

context.

• The

omnidbcheck -bf

command reports that one or several DC

binary files are missing or of incorrect size, or the

omnidbcheck -dc

command reports that one or several DC binary files are corrupted.

• The

debug.log

file on the Cell Manager, located in the

\log\debug.log

(Windows systems) or

in the

/var/opt/omni/log/debug.log

(UNIX systems) contains

one or several entries on Data Protector not being able to open a DC
binary file.

Action

Recreate DC binary files by importing catalog from media. For more
information refer to “Handling Minor Database Corruption in the DCBF
Part” on page 422.

Performance Problems

The number of IDB objects and IDB objects' sizes are too large

When browsing object versions and single files for restore, it can take a
long time before the information is read from the IDB and displayed.