beautypg.com

Troubleshooting data protector installation – HP B6960-90078 User Manual

Page 618

background image

Troubleshooting

Troubleshooting Data Protector Installation

Chapter 12

588

Troubleshooting Data Protector Installation

If you run into problems while installing the Data Protector software,
check the system's log files on UNIX and setup log files on Windows to
determine the problem:

If the setup log files were not created, run the installation with the

-debug

option.

Problems with Remote Installation of Windows
Clients

When using Data Protector remote installation to update Windows
clients, you get the following error:

Error starting setup process, err=[1326] Logon failure:

unknown user name or bad password.

The problem is that the

Data Protector Inet

service on the remote

computer is running under a user account that does not have access to
the OmniBack II share on the Installation Server computer. This is most
probably a local user.

Action

Change the user name for the

Data Protector Inet

service that can

access the OmniBack II share.

System

Log File

UNIX (local installation)

/var/adm/sw/swinstall.log

/var/adm/sw/swagent.log

UNIX (remote installation)

/var/opt/omni/log/IS_install.log

Windows (local installation)

:\\OB2_Setup_

ui__.txt

Windows (remote installation)

:\\OB2_Setup_

exe__.txt