HP B6960-90078 User Manual
Page 380

Monitoring, Reporting, Notifications, and the Event Log
Data Protector Notifications
Chapter 7
350
Windows NT
To configure Windows NT SNMP traps, proceed as follows:
1. On the Cell Manager, open
Control Panel
,
Network
,
Services
. If
there is no SNMP Service entry in the list of network services under
the Services tab, perform step 2. If there is, skip step 2.
2. Click
Add
and select
SNMP Service
. Click
OK
. Insert the Windows
NT installation CD, or provide an alternative path to the requested
files. Click
Continue
.
3. Select
SNMP Service
and click
Properties
. Select the
Traps
tab
and enter
public
in the
Community Name
drop-down list. Click
Add
next to the
Community Name
drop-down list.
4. Click
Add
under
Trap Destinations
text box and enter the
hostname of the VPO Management Server. Click
Add
. Repeat this
step to add any number of VPO Management Servers.
5. Click
OK
. Click
Close
.
6. Start
omnisnmp
.
Windows
2000/XP/Server
2003
To configure Windows 2000/XP/Server 2003 SNMP traps, proceed as
follows:
1. On the Cell Manager, open
Settings
,
Network and Dial-up
Connections
.
2. In the
Advanced
menu, select
Optional Networking Components
to start the wizard.
3. In the wizard, select
Management and Monitoring
tools and click
Next
.
4. Follow the wizard to install the
Management
and
Monitoring
tools.
5. Open
Control Panel
,
Administrative Tools
,
Services
.
6. Right-click
SNMP Service
and select
Properties
.
a. Select the
Traps
tab and enter
public
in the
Community name
text box and the hostname of the VPO Management Server in the
Trap Destinations
text box.
b. Select the
Security
tab. Under
Accepted community names
,
select the community
public
, click
Edit
and set
Community
rights
to
READ CREATE
.
c. Confirm your settings.