Troubleshooting

Troubleshooting the IDB

Chapter 12

595

Problems While Running the User Interface

IDB is corrupted

Any of the following messages can be displayed:

Database is corrupted.

Interprocess communication problem.

Cannot open Database/File.

Error - Details Unknown.

Action

Recover the IDB. For more information, refer to “Recovering the IDB” on
page 417.

The IDB Session Manager is not running on the Cell Manager

If the IDB Session Manager is not running on the Cell Manager when
Data Protector tries to access or use the IDB, the

Interprocess

communication problem error

message is displayed.

• On Windows Cell Manager, the Data Protector process

dbsm.exe

is

not displayed among the processes in the Windows Task Manager.

• On UNIX Cell Manager, the

/opt/omni/lbin/dbsm

is not displayed

when listing the Data Protector processes using the ps

-ef | grep

omni

command.

Action

Close and restart the Data Protector GUI.

Libraries (Executables) Missing

On Windows Cell Managers, the following library files should exist in the

\bin directory

:

libob2ecmn.dll, libob2eadm.dll, libob2ecdb.dll,

libob2emmdb.dll, _eadm32.dll, _erdm32.dll

On UNIX Cell Managers, the following library files should exist in the

/opt/omni/lib

directory:

libob2ecmn.sl, libob2eadm.sl, libob2ecdb.sl,

libob2emmdb.sl, _eadm.sl, _erdm.sl