beautypg.com

Notification send methods – HP B6960-90078 User Manual

Page 377

background image

Monitoring, Reporting, Notifications, and the Event Log

Data Protector Notifications

Chapter 7

347

For more information on the Data Protector checking and maintenance
mechanism, refer to “Data Protector Checking and Maintenance
Mechanism” on page 605
.

Health Check Failed As a part of the Data Protector checking and
maintenance mechanism, Data Protector will by default once per day
start the Health Check, which starts the

omnihealthcheck

command

and triggers the notification if the

omnihealthcheck

command fails. For

more information on the

omnihealthcheck

command, refer to the

omnihealthcheck

man page. The

omnihealthcheck

command checks:

• whether the Data Protector services (

rds

,

crs

,

mmd

,

omnitrig

, and

OmniInet

) are active

• whether the Media Management database is consistent

• whether at least one backup of the IDB exists

The exit code of the command is 0 (OK) only if all three checks completed
successfully (exit code for every check was 0). Exit values other than 0
indicate that one of the checks failed. For more information on exit codes,
refer to the

omnihealthcheck

man page.

User Check Failed By default, once per day Data Protector will start
the User Check, which executes the script/command specified as the