ADIC/GRAU DAS and STK ACS Libraries
The ADIC/GRAU DAS Library Device
Chapter 14
670
• Enter the
Device Name
and, below,
Description
.
• In the
Client
text box choose the DAS Media Agent client from the
list that will access ADIC/GRAU robotics.
• Choose the
GRAU DAS Library
in the
Device
type
text box. In the
DAS Server
enter the hostname of the DAS Server (obtained
information during installing DAS Agent).
• Choose preferred action from the list for the
Busy Drive
situation.
Insert the
Import and Export Areas
for the media type this Data
Protector library is configured for (obtained information during
installing DAS Agent).
• Choose appropriate
Media Type
from the list.
Using Data Protector to Configure Drives
Create a library for each type of media that you will use with Data
Protector. The steps to add a drive to a ADIC/GRAU library are as
follows:
• Switch to the
Devices & Media
context. Choose created device,
right-click
Drives
, and then
Add Drive
. Enter the
Device Name
and
Description
.
• In the
Client
text box enter the hostname where the ADIC/GRAU
media device is connected.
• In
Data Drive
enter the SCSI address of the device.
• In the
Drive Name
enter the ADIC/GRAU Drive name you
remembered during installing the DAS Agent. Select the appropriate
Media Pool
you created for this Drive.
• Select
Advanced Options
to change
Concurrency
and other settings
as necessary. Note that the
Force Direct Library Access
option is
not selected by default. Turn this option off when choosing the
indirect library robotics access configuration (for more information,
see the following section, “Indirect Access to the DAS Library:
Installation and Configuration”).
Indirect Access to the DAS Library: Installation and
Configuration
This section focuses on the indirect access configuration.