HP B6960-90078 User Manual
Page 531

Disaster Recovery
Manual Disaster Recovery of an HP-UX Client
Chapter 10
501
impacts = "/stand" 1116Kb
impacts = "/tcadm" 1Kb
impacts = "/usr" 729579Kb
impacts = "/var" 254639Kb
7. To make Ignite-UX aware of the new created depot, add an
cfg
entry
to the
/var/opt/ignite/INDEX
file with the following layout:
cfg "
description "
"/opt/ignite/data/
"/var/opt/ignite/data/
}
Example
cfg "HPUX11_11_DP50_Client" {
description "HPUX 11.i OS incl Patches and DP50 Client"
"/opt/ignite/data/Rel_B.11.11/config"
"/var/opt/ignite/data/Rel_B.11.11/archive_HPUX11_11_DP50_CL.cfg
"
}
8. Make sure that one or more IP addresses reserved for booting clients
are configured in the
/etc/opt/ignite/instl_boottab
file. The
number of IP addresses is equal to the number of parallel booting
clients.
After the above described procedure is completed, you have a Golden
Image of an HP-UX client (with a specific hardware and software
configuration), which can be used to recover any client of a similar
layout.
You have to repeat these steps to create a Golden Image for all systems
with different hardware and software configuration.