653

To enable automatic forwarding of all Data Protector messages and
messages about the Data Protector services (if they are stopped) to
Windows Application Log, set the

EventLogMessages

variable in the

Data Protector global options file to

1

. For more information on Data

Protector global options file refer to “Global Options File” on page 523.

Examples

Verifying Data Protector Processes

Data Protector provides a means of checking if its required processes are
running by the means of the

omnisv -status

CLI command.

The

omnisv -status

command provides you with the status of the

required Data Protector processes (when the command is started).

omnisv -status

To get the status of required Data Protector processes enter the following
command:

omnisv -status

Data Protector Health Check Failed Notification

The User Health Check notification is triggered and sent only if any of
the required processes are not running or if the IDB is not operational.
The Health Check Failed notification by default checks these conditions
every day at 12:00 (Noon) and is (if the conditions are met), by default
sent to Data Protector Event Log. You can change the scheduled time by
changing the

DailyMaintenanceTime

variable, using the twenty-four

hour clock notation, in the Data Protector global options file. For more
information on Data Protector global options file refer to “Global Options
File” on page 523.
You can also redirect the notification to be sent, for
example as an SNMP trap.

To check every day at the scheduled time if the required Data Protector
processes are running and if the IDB is operational, and to be notified by
an SNMP trap if any of the processes are not running or if database is
not operational, configure the Health Check Failed notification as
described in the “Data Protector Notifications” on page 342.

To check the conditions of the Health Check Failed notification
interactively, enter the following command:

omnihealthcheck