Control circuit terminal functions – Yaskawa Matrix Converter User Manual
Page 53
Wiring Control Circuit Terminals
2-
19
Control Circuit Terminal Functions
The functions available by using the control circuit terminals are shown in Table 2.8. Use the appropriate ter-
minals for the correct purposes.
Table 2.8 Control Circuit Terminals
Type
No.
Signal Name
Function
Signal Level
Se-
quence
input
signals
S1
Forward Run/Stop Command Forward run when on, stopped when off.
24 VDC, 8 mA
Photocoupler isolation
S2
Reverse Run/Stop Command Reverse run when on, stopped when off.
S3
Multi-Function Input 1
*1
Default: External Fault when on.
S4
Multi-Function Input 2
*1
Default: Fault Reset when on.
S5
Multi-Function Input 3
*1
Default: Multi-Speed Reference 1 enabled
when on.
S6
Multi-Function Input 4
*1
Default: Multi-Speed Reference 2 enabled
when on.
S7
Multi-Function Input 5
*1
Default: Jog Frequency selected when on.
S8
Multi-Function Input 6
*1
Default: External Baseblock when on.
S9
Multi-Function Input 7
*1
Default: Multi-Speed Reference 3 enabled
when on.
S10
Multi-Function Input 8
*1
Default: Multi-Speed Reference 4 enabled
when on.
S11
Multi-Function Input 9
*1
Default: Accel/Decel Time selected when on.
S12
Multi-Function Input 10
*1
Default: Emergency Stop (N.O. contact)
when on.
SC
Sequence input common
-
Analog
input
signals
+V
+15 V power output
+15 V power supply for analog references
+15 V
(Max current: 20 mA)
-V
-15 V power output
-15 V power supply for analog references
-15 V
(Max current: 20 mA)
A1
Master Speed Frequency
Reference
-10 to +10 V/-100 to 100%
0 to +10 V/100%
-10 to +10 V, 0 to +10 V
(Input impedance:
20 k
Ω)
A2
Multi-Function Analog Input
4 to 20 mA/100%, -10 to +10 V/-100 to
+100%, 0 to +10 V/100%
Default: Added to terminal A1
(H3-09 = 0)
4 to 20 mA (Input imped-
ance: 250
Ω)
-10 to +10 V, 0 to +10 V
(Input impedance:
20 k
Ω)
A3
Multi-Function Analog Input
-10 to +10 V/-100 to +100%, 0 to +10 V/
100%
Default: Analog speed 2 (H3-05 = 2)
-10 to +10 V, 0 to +10 V
(Input impedance:
20 k
Ω)
AC
Analog reference common
0 V
-
E(G)
Shield wire, optional ground
line connection point
-
-