D: reference, D1: preset reference – Yaskawa Matrix Converter User Manual
Page 120

5
-20
d: Reference
The following settings are made with the reference parameters (d parameters): Frequency references.
d1: Preset Reference
Parameter
Number
Name
Description
Setting
Range
Default
Change
during
Run
Control
Methods
MEMO-
BUS
Register
Page
Display
V/f
Open
Loop
Vector
Flux
Vector
d1-01
Frequency
Reference 1
Sets the frequency reference in the units
used in o1-03.
0.00 to
120.00
*
0.00
Hz
Yes
Q
Q
Q
280H
4-4
6-5
Reference 1
d1-02
Frequency
Reference 2
The frequency reference when multi-step
speed reference 1 is on for a multi-func-
tion input (unit: Set in o1-03).
0.00
Hz
Yes
Q
Q
Q
281H
4-4
6-5
Reference 2
d1-03
Frequency
Reference 3
The frequency reference when multi-step
speed reference 2 is on for a multi-func-
tion input (unit: Set in o1-03).
0.00
Hz
Yes
Q
Q
Q
282H
4-4
6-5
Reference 3
d1-04
Frequency
Reference 4
The frequency reference when multi-step
speed references 1 and 2 are on for multi-
function inputs (unit: Set in o1-03).
0.00
Hz
Yes
Q
Q
Q
283H
4-4
6-5
Reference 4
d1-05
Frequency
Reference 5
The frequency when multi-step speed ref-
erence 3 is on for a multi-function input
(unit: Set in o1-03).
0.00
Hz
Yes
A
A
A
284H
6-5
Reference 5
d1-06
Frequency
Reference 6
The frequency reference when multi-step
speed references 1 and 3 are on for multi-
function inputs (unit: Set in o1-03).
0.00
Hz
Yes
A
A
A
285H
6-5
Reference 6
d1-07
Frequency
Reference 7
The frequency reference when multi-step
speed references 2 and 3 are on for multi-
function inputs (unit: Set in o1-03).
0.00
Hz
Yes
A
A
A
286H
6-5
Reference 7
d1-08
Frequency
Reference 8
The frequency reference when multi-step
speed references 1, 2, and 3 are on for
multi-function inputs (unit: Set in o1-03).
0.00
Hz
Yes
A
A
A
287H
6-5
Reference 8
d1-09
Frequency
Reference 9
The frequency reference when multi-step
speed reference 4 is on for a multi-func-
tion input (unit: Set in o1-03).
0.00
Hz
Yes
A
A
A
288H
-
Reference 9
d1-10
Frequency
Reference 10
The frequency reference when multi-step
speed references 1 and 4 are on for multi-
function inputs (unit: Set in o1-03).
0.00
Hz
Yes
A
A
A
28BH
-
Reference 10
d1-11
Frequency
Reference 11
The frequency reference when multi-step
speed references 2 and 4 are on for a
multi-function inputs (unit: Set in o1-03).
0.00
Hz
Yes
A
A
A
28CH
-
Reference 11
d1-12
Frequency
Reference 12
The frequency reference when multi-step
speed references 1, 2, and 4 are on for
multi-function inputs (unit: Set in o1-03).
0.00
Hz
Yes
A
A
A
28DH
-
Reference 12
* The upper limit of the setting range depends on the upper limit set at E1-04. The maximum allowable setting is 120.00.