Main Circuit Terminal Functions
Main circuit terminal functions are summarized according to terminal symbols in Table 2.4. Wire the terminals
correctly for the desired purpose.
* 1. Connect the momentary power loss compensation unit. Do not connect power to these terminals.
* 2. Normally not used. Do not connect power to these terminals.
* 3. The MxC models CIMR-ACA4110 and 4160 do not have terminals r2, s2, t2, p1 and n1.
Main Circuit Configurations
The main circuit configurations of the MxC are shown in Fig 2.7.
CIMR-ACA25P5 to 2045, 45P5 to 4160
* 1. Connect the momentary power loss compensation unit. Do not connect power to these terminals.
* 2. Normally not used. Do not connect power to these terminals.
* 3. The MxC models CIMR-ACA4110 and 4160 do not have terminals r2, s2, t2, p1 and n1.
Note: Control power is supplied internally from the main circuit power supply for all MxC models.
Fig 2.7 MxC Main Circuit Configurations
Table 2.4 Main Circuit Terminal Functions
(200 V class and 400 V class)
Purpose
Terminal symbols
Main circuit power input
R/L1, S/L2, T/L3
MxC output
U/T1, V/T2, W/T3
Ground
Connection to optional devices
r2
*2 *3
, s2
*2 *3
, t2
*2 *3
, p1
*1 *3
,
n1
*1 *3
t2
*
2 *3
Control
circuit
R/L1
S/L2
T/L3
U/T1
V/T2
W/T3
r2
*
2 *3
s2
*
2 *3
p1
*
1 *3
n1
*
1 *3
Input filter
Power supply