Yaskawa Matrix Converter User Manual
Page 305
6
-140
Setting Output Items for the DO-08 Digital Output Card
If using DO-08 Digital Output Card, select one of the following three output modes according to the setting in
F5-09.
F5-09 Set to 0
F5-09 Set to 1
The following table shows the code outputs.
F5-09 Set to 2
Output depends on the settings in F5-01 to F5-08.
Set Value
Terminal
Number
Output Details
0: 8 separate
outputs
TD5-TD11
Overcurrent (OC, GF)
TD6-TD11
Overvoltage (OV, AOV)
TD7-TD11
MxC overload (OL2, OH2)
TD8-TD11
Not used
TD9-TD11
Overspeed (OS)
TD10-TD11
MxC overheated (OH1) or motor overload (OL1)
TD1-TD2
Zero-speed detected
TD3-TD4
Speed Agree
Set Value
Terminal
Number
Output Details
1: Binary code
output
TD5-TD11
bit 0
Encoded output
(Refer to table below)
TD6-TD11
bit 1
TD7-TD11
bit 2
TD8-TD11
bit 3
TD9-TD11
Zero-speed detected
TD10-TD11
Speed Agree
TD1-TD2
Operating
TD3-TD4
Minor fault
Bits 3, 2, 1,
and 0
Output Details
Bits 3, 2, 1,
and 0
Output Details
0000
No error
1000
External fault (EF
)
0001
Overcurrent (OC, GF)
1001
Controller error (CPF
)
0010
Overvoltage (OV, AOV)
1010
Motor overload (OL1)
0011
MxC overload (OL2, OH2)
1011
Not used
0100
MxC overheated (OH, OH1)
1100
Power loss (UV1, UV2, FDV, AUV, or SRC)
0101
Overspeed (OS)
1101
Speed deviation (DEV)
0110
Not used
1110
PG Disconnect (PGO)
0111
Built-in resistor overheated (SOH, DOH)
1111
Not used