Related parameters – Yaskawa Matrix Converter User Manual
Page 202
![background image](https://www.manualsdir.com/files/819680/content/doc202.png)
Improved Operating Efficiency
6-
37
Stabilizing Speed (Speed Feedback Detection Function)
The speed feedback detection control (AFR) function measures the stability of the speed when a load is sud-
denly applied by calculating the amount of fluctuation of the torque current feedback value, and compensating
the output frequency with the amount of fluctuation.
Related Parameters
Parameter
Number
Name
Description
Setting
Range
Default
Change
during
Run
Control Methods
Display
V/f
Open
Loop
Vector
Flux
Vector
n2-01
Speed Feedback
Detection Control
(AFR) Gain
Set the internal speed feedback detection con-
trol gain using the multiplication function.
Normally, there is no need to make this set-
ting.
Adjust this parameter as follows:
• If hunting occurs, increase the set value.
• If response is low, decrease the set value.
Adjust the setting by 0.05 at a time, while
checking the response.
0.00 to
10.00
1.00
No
No
A
No
AFR Gain
n2-02
Speed Feedback
Detection Control
(AFR) Time Con-
stant
Set the time constant to decide the rate of
change in the speed feedback detection con-
trol.
0 to
2000
100 ms
No
No
A
No
AFR Time
n2-03
Speed Feedback
Detection Control
(AFR) Time Con-
stant 2
Increase the setting if overvoltage (OV) fail-
ures occur at the completion of acceleration or
when the load changes radically.
0 to
2000
750 ms
No
No
A
No
AFR Time 2