Defaults for various mxc capacities (o2-04) – Yaskawa Matrix Converter User Manual
Page 165
Parameter Tables
5-
65
* 1. These are setting range and default value for a 200 V class MxC. Values for a 400 V class MxC are double.
* 2. Settings vary as shown in the following tables depending on the MxC capacity and E1-03.
200 V and 400 V Class MxCs of 5.5 to 75 kW
* The setting shown are for 200 V class MxCs. The values will double for 400 V class MxCs.
Defaults for Various MxC Capacities (o2-04)
If the MxC capacity (o2-04) is changed, the defaults of the following parameters will change.
F1-09
Overspeed Detection Delay Time
0.0 to 2.0
0.1 s
-
-
0.0
PG Overspd Time
Parameter
Number
Unit
Default
Open
Loop
Vector
Control
Flux
Vector
Control
E1-03
-
0
1
2
3
4
5
6
7
8
9
A
B
C
D
F
E1-04
Hz
50.0
60.0
60.0
72.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
90.0
120.0
60.0
60.0
60.0
E1-05 *
V
200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
200.0
200.0
E1-06
Hz
50.0
60.0
50.0
60.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
60.0
60.0
60.0
60.0
0.0
E1-07
Hz
2.5
3.0
3.0
3.0
25.0
25.0
30.0
30.0
2.5
2.5
3.0
3.0
3.0
3.0
3.0
3.0
0.0
E1-08 *
V
14.0
14.0
14.0
14.0
35.0
50.0
35.0
50.0
18.0
23.0
18.0
23.0
14.0
14.0
14.0
13.0
0.0
E1-09
Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
1.3
1.3
1.5
1.5
1.5
1.5
1.5
0.5
0.0
E1-10 *
V
7.0
7.0
7.0
7.0
6.0
7.0
6.0
7.0
9.0
11.0
9.0
13.0
7.0
7.0
7.0
2.5
0.0
Parameter
Number
Name
Unit
Default
200 V class
400 V class
-
MxC Capacity
kW
5.5
11
22
45
5.5
11
22
45
75
110 160
E2-11
Motor Rated Output
E4-07
Motor 2 Rated Output
o2-04
MxC/kVA Selection
-
5
7
A
D
26
28
2B
2E
30
32
34
E2-01
(E4-01)
Motor Rated Current
A
19.60 39.7
77.2 160.0 9.80
19.9
38.6
79.7 130.0 190.0 270.0
E2-02
(E4-02)
Motor Rated Slip
Hz
1.50
1.70
1.70
1.60
1.50
1.70
1.70
1.60
1.39
1.40
1.35
E2-03
(E4-03)
Motor No-Load Current
A
5.10
11.2
18.5
44.0
2.60
5.6
9.2
22.0
36.0
49.0
70.0
E2-05
(E4-05)
Motor Line-to-Line Resis-
tance
Ω
0.399 0.230 0.079 0.030 1.595 0.922 0.316 0.122 0.092 0.046 0.029
E2-06
(E4-06)
Motor Leakage Inductance
%
18.2
19.5
19.5
20.2
18.2
19.6
23.5
19.9
20.0
20.0
20.0
E2-10
Motor Iron Loss for Torque
Compensation
W
172
245
538
852
193
385
586
1125 1600 2150 2850
n5-02
Motor Acceleration Time
s
0.168 0.265 0.355 0.387 0.168 0.265 0.355 0.387 0.533 0.646 0.777
L8-02
Overheat Alarm Level
°C
90
90
85
90
85
85
85
90
90
1.7
1.9
L2-03
Momentary Power Loss
Minimum Base Block Time
s
0.7
0.9
1.1
0.7
0.7
0.9
1.1
1.2
1.5
115
115
Parameter
Number
Name
Setting Range
Unit
Default
Display
V/f
Control
Open loop
Vector
Flux
Vector