Yaskawa Matrix Converter User Manual
Page 138
![background image](https://www.manualsdir.com/files/819680/content/doc138.png)
5
-38
* Applicable for the Varispeed AC with software versions PRG:1050 or later.
E
Fault (ON: Digital operator communications error or fault other than CPF00 and
CPF01 has occurred).
Yes
Yes
Yes
-
F
Not used (Set when the terminals are not used).
-
-
-
-
10
Minor fault (ON: Alarm displayed)
Yes
Yes
Yes
-
11
Fault Reset Command active
Yes
Yes
Yes
-
12
Timer function output
Yes
Yes
Yes
6-93
13
Frequency agree 2 (L4-04 used)
Yes
Yes
Yes
6-45
14
Desired frequency agree 2 (ON: Output frequency = L4-03, L4-04 used, and during
frequency agree)
Yes
Yes
Yes
6-45
15
Frequency detection 3 (ON: Output frequency
≤ -L4-03, L4-04 used)
Yes
Yes
Yes
6-45
16
Frequency detection 4 (ON: Output frequency
≥ -L4-03, L4-04 used)
Yes
Yes
Yes
6-45
17
Overtorque/undertorque detection 1 NC (NC Contact: Torque detection at off)
Yes
Yes
Yes
6-49
18
Overtorque/undertorque detection 2 NO (NO Contact: Torque detection at on)
Yes
Yes
Yes
6-49
19
Overtorque/undertorque detection 2 NC (NC Contact: Torque detection at off)
Yes
Yes
Yes
6-49
1A
During reverse run (ON: During reverse run)
Yes
Yes
Yes
-
1B
During baseblock 2 (OFF: During baseblock)
Yes
Yes
Yes
-
1C
Motor selection (Motor 2 selected)
Yes
Yes
Yes
-
1D
During regeneration (ON: During regeneration)
No
No
Yes
-
1E
Restart enabled (ON: Restart enabled.)
Yes
Yes
Yes
6-65
1F
Motor overload (OL1, including OH3) pre-alarm (ON: 90% or more of the detection
level)
Yes
Yes
Yes
6-51
6-78
20
MxC overheat (OH) pre-alarm (ON: Temperature exceeds L8-02 setting)
Yes
Yes
Yes
6-78
2F
*
Maintenance Time
ON: The operation time of either the capacitors on the PCB board or the cooling fan
have reached the specified maintenance time.
Yes
Yes
Yes
6-155
30
During torque limit (current limit) (ON: During torque limit)
No
Yes
Yes
-
31
During speed limit (ON: During speed limit)
No
No
Yes
6-78
32
Speed control circuit operating for torque control (except when stopped).
The external torque reference will be limited if torque control is selected (internal
torque reference < external torque reference).
Output when the motor is rotating at the speed limit.
No
No
Yes
6-109
33
Zero-Servo Complete (ON: Zero-servo function completed)
No
No
Yes
6-78
6-123
36
Frequency (FOUT) detection 5 (ON: Output frequency is equal to or greater than the
set value of +L4-01 or equal to or less than the set value of
−L4-01 and L4-02 is used,
off during base blocked)
Yes
Yes
Yes
6-44
37
During Run 2 (ON: Frequency output, off: Baseblock, DC Injection Braking, initial
excitation, operation stop)
Yes
Yes
Yes
6-77
Set
Value
Function
Control
Methods
Page
V/f
Open
Loop
Vector
Flux
Vector