D5: torque control – Yaskawa Matrix Converter User Manual
Page 123
Parameter Tables
5-
23
d5: Torque Control
Parameter
Number
Name
Description
Setting
Range
Default
Change
during
Run
Control
Methods
MEMO-
BUS
Register
Page
Display
V/f
Open
Loop
Vector
Flux
Vector
d5-01
Torque Control
Selection
0: Speed control (C5-01 to C5-07)
1: Torque control
This function is only available in Flux
Vector Control method. To use the func-
tion for switching between speed and
torque control, set to 0 and set the multi-
function input to “speed/torque control
change.”
0 or 1
0
No
No
No
A
29AH
6-108
Torq Control Sel
d5-02
Torque Reference
Delay Time
Set the torque reference delay time in ms
units.
This function can be used to adjust the
noise of the torque control signal or the
responsiveness with the host controller.
When oscillation occurs during torque
control, increase the set value.
0 to
1000
0 ms
No
No
No
A
29BH
6-108
Torq Ref Filter
d5-03
Speed Limit
Selection
Set the speed limit command method for
the torque control method.
1: The analog input limit from a fre-
quency reference
2: Limited by d5-04 setting values.
1 or 2
1
No
No
No
A
29CH
6-108
Speed Limit Sel
d5-04
Speed Limit
Set the speed limit during torque control
as a percentage of the maximum output
frequency.
This function is enabled when d5-03 is
set to 2. Directions are as follows.
+: Run Command direction
-: Run Command opposite direction
-120 to
+120
0%
No
No
No
A
29DH
6-108
Speed Lmt Value
d5-05
Speed Limit Bias
Set the speed limit bias as a percentage of
the maximum output frequency.
Bias is given to the specified speed limit.
It can be used to adjust the margin for the
speed limit.
0 to 120
10%
No
No
No
A
29EH
6-108
Speed Lmt Bias
d5-06
Speed/Torque
Control
Switchover Timer
Set the delay time from inputting the
multi-function input “speed/torque con-
trol change” (from on to off or off to on)
until the control is actually changed, in
ms units.
This function is enabled when the multi-
function input “speed/torque control
change” is set. In the speed/torque control
switching timer, the analog inputs hold
the values of when the “speed/torque con-
trol change” changes. Always be sure to
allow time for this process to finish com-
pletely.
0 to
1000
0 ms
No
No
No
A
29FH
6-108
Ref Hold Time