F6: communications option cards – Yaskawa Matrix Converter User Manual
Page 133
Parameter Tables
5-
33
F6: Communications Option Cards
F5-09
DO-08 Output
Mode Selection
Sets the function of the DO-08 digital
output option card.
0: 8-channel individual outputs.
1: Binary code output.
2: 8-channel Selected - Output accord-
ing to F5-01 to F5-08 settings.
0 to 2
0
No
A
A
A
3A1H
6-139
DO-08 Selection
Parameter
Number
Name
Description
Setting
Range
Default
Change
during
Run
Control
Methods
MEMO-
BUS
Register
Page
Display
V/f
Open
Loop
Vector
Flux
Vector
F6-01
Operation Selec-
tion after Com-
munication Error
Selects the stopping method for a com-
munication option card fault (BUS).
Active only when a communication
option card is installed and b1-01 or b1-
02 = 3.
0: Decelerate to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only
0 to 3
1
No
A
A
A
3A2H
-
Comm Bus Flt Sel
F6-02
Selection of
External Fault
from Communi-
cation Option
Card
Selects the condition in which an EF0
fault is detected from a communication
option card. Active only when a commu-
nication option card is installed and b1-01
or b1-02 = 3.
0: Always detected.
1: Detected only during run.
0 or 1
0
No
A
A
A
3A3H
-
EF0 Detection
F6-03
Stopping Method
for External Fault
from Communi-
cation Option
Card
Selects the stopping method for an exter-
nal fault from a communication option
card (EF0). Active only when a commu-
nication option card is installed and b1-01
or b1-02 = 3.
0: Decelerate to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only
0 to 3
1
No
A
A
A
3A4H
-
EF0 Fault Action
F6-04
Trace Sampling
from Communi-
cations Option
Card
−
0 to
60000
0
No
A
A
A
3A5H
-
Trace Sample Tim
F6-06
Torque Reference/
Torque Limit
Selection from
Communications
Option
Selects torque reference/limit when using
communications option card.
0: Disabled. - Torque reference/limit
from option card disabled
1: Enabled.- Torque reference/limit from
option card enabled.
0 or 1
0
No
No
No
A
3A7H
-
Torq Ref/Lmt Sel
Parameter
Number
Name
Description
Setting
Range
Default
Change
during
Run
Control
Methods
MEMO-
BUS
Register
Page
Display
V/f
Open
Loop
Vector
Flux
Vector