Yaskawa Matrix Converter User Manual
Page 393
Parameters
10-
23
10
Table 10.2 Parameters (Continued)
L8-12
Ambient Temperature Setting
45
L8-15
OL2 Characteristic Selection at
Low Speeds
1
L8-42
Factory Adjustment 1
2
n1-01
Hunting Prevention Selection
1
n1-02
Hunting Prevention Gain Setting
1.00
n1-03
Hunting Prevention Time Constant
10
n2-01
Speed Feedback Detection Con-
trol (AFR) Gain
1.00
n2-02
Speed Feedback Detection Con-
trol (AFR) Time Constant
100
n2-03
Speed Feedback Detection Con-
trol (AFR) Time Constant 2
750
n5-01
Feed Forward Control Selection
0
n5-02
Motor Acceleration Time
0.168
*3
n5-03
Feed Forward Control Ratio Gain
1.0
o1-01
User Monitor Selection
6
o1-02
User Monitor Selection After
Power-Up
1
o1-03
Digital Operator Display Selection
0
o1-04
Setting unit for frequency parame-
ters related to V/f characteristics
0
o1-05
LCD Brightness Adjustment
3
o2-01
Local/Remote Key Function Selec-
tion
1
o2-02
STOP Key Function Selection
1
o2-03
User Parameter Default Value
0
o2-04
MxC/kVA Selection
5
*2
o2-05
Frequency Reference Setting
Method Selection
0
No.
Name
Default
Set-
ting
o2-06
Operation Selection when Digital
Operator is Disconnected
0
o2-07
Cumulative Operation Time Set-
ting
0
o2-08
Cumulative Operation Time Selec-
tion
0
o2-09
Initialization Specification Selec-
tion
0
o2-10
Fan operation time setting
0
o2-12
Fault Trace/Fault History Clear
Function
0
o2-14
kWh User Monitor Initialization
0
o2-18
*7
Capacitor maintenance setting
0
o3-01
Copy Function Selection
0
o3-02
Copy Allowed Selection
0
T1-00
Motor Selection 1/2
1
T1-01
Auto-Tuning Mode Selection
0
T1-02
Motor Rated Power
5.50
*2
T1-03
Motor Rated Voltage
200.0
*3
T1-04
Motor Rated Current
19.60
*2
T1-05
Motor Base Frequency
60.0
T1-06
Number of Motor Poles
4
T1-07
Motor Base Speed
1750
T1-08
Number of PG Pulses
600
T1-09
Motor No-Load current
5.10
T1-10
Motor Rated Slip
1.50
No.
Name
Default
Set-
ting
Table 10.2 Parameters (Continued)
* 1. The default will change when the control method is changed. The Open Loop Vector defaults are given.
* 2. The defaults depend on the MxC capacity. The values for a 200 V class MxC of 5.5 kW are given.
* 3. These are values for a 200 V class MxC. Values for a 400 V class MxC are double.
* 4. E1-11 and E1-12 are disregarded when set to 0.0.
* 5. E1-13 is set to the same value as E1-05 by Auto-Tuning.
* 6. The defaults in the parentheses are for 3-wire sequence.
* 7. Applicable for the Varispeed AC with software versions PRG: 1050 or later.
* 8. Applicable for the Varispeed AC with software versions PRG: 1052 or later.