Parameters – Yaskawa Matrix Converter User Manual
Page 387
Parameters
10-
17
10
Parameters
Defaults in the MxC are listed below. These settings are for a 200 V class 5.5 kW MxC set to Open Loop
Vector Control (the factory default control method).
Table 10.2 Parameters
No.
Name
Default
Set-
ting
A1-00 Language Selection
1
A1-01 Access Level Selection
2
A1-02 Control Method Selection
2
A1-03 Initialize Parameters
0
A1-04 Password 1
0
A1-05 Password 2
0
A2-01 to
A2-32
User Parameters
-
b1-01
Frequency Reference Selection
1
b1-02
Run Command Selection
1
b1-03
Stopping Method Selection
0
b1-04
Reverse Operation Selection
0
b1-05
Minimum Output Frequency (E1-
09) or Less Operation Selection
0
b1-06
Digital Input Scan Time
1
b1-07
Local/Remote Run Selection
0
b1-08
Run Command Selection During
Program
0
b2-01
DC Injection Braking Start Fre-
quency
0.5
b2-02
DC Injection Braking Current
50
b2-03
DC Injection Braking Time/DC
Excitation Time at Start
0.00
b2-04
DC Injection Braking Time at Stop
0.50
b2-08
Magnetic Flux Compensation
Capacity
0
b3-01
Speed Search Selection
0
b3-02
Speed Search Deactivation Current 100
*1
b3-03
Speed Search Deceleration Time
2.0
No.
Name
Default
Set-
ting
b3-04
*8
Current Suppression Gain During
Search
100
*2
b3-05
Speed Search Delay Time
0.2
b3-10
Speed Search Detection Compen-
sation Gain
1.05
b3-14
Bi-Directional Speed Search
Selection
0
b3-19
Number of Speed Search Restarts
1
b4-01
Timer Function ON-Delay Time
0.0
b4-02
Timer Function OFF-Delay Time
0.0
b5-01
PID Function Setting
0
b5-02
Proportional Gain Setting
1.00
b5-03
Integral Time Setting
1.0
b5-04
Integral Limit Setting
100.0
b5-05
Derivative Time
0.00
b5-06
PID Output Limit
100.0
b5-07
PID Offset Adjustment
0.0
b5-08
PID Primary Delay Time Constant
0.00
b5-09
PID Output Level Selection
0
b5-10
PID Output Gain Setting
1.0
b5-11
PID Output Reverse Selection
0
b5-12
PID Feedback Reference Missing
Detection Selection
0
b5-13
PID Feedback Loss Detection
Level
0
b5-14
PID Feedback Loss Detection
Time
1.0
b5-15
PID Sleep Function Start Level
0.0
b5-16
PID Sleep Delay Time
0.0