beautypg.com

Zero point c-axis object center g773 – HEIDENHAIN SW 54843x-03 DIN Programming User Manual

Page 463

background image

HEIDENHAIN MANUALplus 620, CNC PILOT 640

463

5.2 T

o

uc

h pr

obe cy

cles f

o

r single-point measur

ement

Zero point C-axis object center G773

Cycle G773 measures an element with the C axis from two opposite
sides and places the center of the element to a defined position. The
result of the measurement is saved additionally in the variable #i99
(See "Touch probe cycles for automatic operation" on page 455.).

Cycle run

From the current position, the element to be probed is moved toward
the touch probe by a rotation of the C axis. When the workpiece
touches the stylus, the measured value is saved and the workpiece is
returned. Then the touch probe is pre-positioned for the opposite
probing procedure. When the second measured value has been
determined, the cycle computes the mean value of the two
measurements and applies a zero point shift in the C axis. The nominal
position AC defined in the cycle is then in the center of the probed
element.

The control outputs an error message if the touch probe does not
reach any touch point within the defined measuring path. If a
maximum deviation WE was programmed, each measuring point is
approached twice and the mean value is saved as result. If the
difference of the measurements is greater than the maximum
deviation WE, the program run is interrupted and an error message is
displayed.

Beispiel: G773—Single-point measurement C-axis
object center

. . .

MACHINING

N3 G773 R1 C20 E0 RB20 RC45 AC30 BD0.2 Q0
P0 H0

. . .

Parameters
R

Type of zero point shift:

1: Table and G152: Activate zero point shift and additionally
save in zero point table. The zero-point shift also remains
active after the program run.

2: Activate zero point shift with G152 for the further program
run. Zero point shift no longer active after program run.

C

Incremental measuring path with direction: Measuring path of
the C axis (in degrees), starting from the current position. The
algebraic sign determines the probing direction.

E

Circumnavigation axis: Axis that is positioned back by RB in
order to circumnavigate the element

RB Circumnavigation direction offset: Retraction value in the

circumnavigation axis E for pre-positioning for the next probing
position

RC C-angle offset: Difference in the C axis between the first and the

second measuring position

AC Nominal value for target position: Absolute coordinate of touch

point in degrees

BD Tolerance +/-: Measurement result range (in degrees) in which

no compensation is applied

KC

Compensation offset: Additional compensation value that is
applied to the zero point result

WE Maximum deviation: Probe twice and monitor the dispersion of

the measured values

F

Measuring feed rate: Feed rate for probing. If nothing is entered,
the measuring feed rate from the touch probe table is used. If
the entered measuring feed rate F is higher than the one in the
touch probe table, the feed rate is reduced to the value from the
touch probe table.

This manual is related to the following products: