Dialog texts in subprogram call, 33 subpr ogr a ms – HEIDENHAIN SW 54843x-03 DIN Programming User Manual
Page 428

428
DIN Programming
4.33 Subpr
ogr
a
ms
Dialog texts in subprogram call
You can define up to 30 parameter descriptions that precede/follow
the input fields in an external subprogram. The units of measure are
defined using code numbers. Depending on the setting "metric" or
"inches," the Steuerung shows the designations (of the units of
measure). When calling external subprograms that contain a
parameter list, then parameters not contained in this list are omitted
from the call dialog.
The parameter descriptions can be positioned within the subprogram
as desired. The control searches for subprograms in the sequence:
current project, standard directory and then machine manufacturer
directory.
Parameter descriptions (see table at right):
[//] – Beginning
[pn=n; s=parameter text (up to 25 characters) ]
[//] – End
pn:
Parameter designations (la, lb, ...)
n:
Code number for units of measure
0: Non-dimensional
1: mm or inches
2: mm/rev or inch/rev
3: mm/min or inch/min
4: m/min or ft/min
5: Rev/min
6: Degrees (°)
7: µm or µinch
Beispiel:
. . .
[//]
[la=1; s=bar diameter]
[lb=1; s=starting point in Z]
[lc=1; s=chamfer/rounding arc (-/+)]
. . .
[//]
. . .