Touch probe cycles
5.2 T
o
uc
h pr
obe cy
cles f
o
r single-point measur
ement
V
Retraction type
0: Without: Only position touch probe back to the starting
point if the touch probe was deflected
1: Automatic: Always position touch probe back to the starting
point
O
Error evaluation
0: Program: Do not interrupt program run, no error message
1: Automatic: Interrupt program run and output error message
if touch probe is not deflected within measuring path
F
Measuring feed rate: Feed rate for probing. If nothing is entered,
the measuring feed rate from the touch probe table is used. If
the entered measuring feed rate F is higher than the one in the
touch probe table, the feed rate is reduced to the value from the
touch probe table.
Q
Tool orientation: Orient the touch probe in the programmed
probing direction before each probing operation (machine-
dependent function)
P
PRINT outputs
0: OFF: Do not display measuring results
1: ON: Display measuring results
H
INPUT instead of measurement
0: Default: Obtain measured values by probing
1: PC test: Simulate probing cycle on the programming station
AN Log no.: Save measurement results in
"TNC:\table\messpro.mep" table (line numbers 0–99; the table
can be expanded if necessary)