beautypg.com

HEIDENHAIN SW 54843x-03 DIN Programming User Manual

Page 458

background image

458

Touch probe cycles

5.2 T

o

uc

h pr

obe cy

cles f

o

r single-point measur

ement

V

Retraction type

0: Without: Only position touch probe back to the starting
point if the touch probe was deflected

1: Automatic: Always position touch probe back to the starting
point

O

Error evaluation

0: Program: Do not interrupt program run, no error message

1: Automatic: Interrupt program run and output error message
if touch probe is not deflected within measuring path

F

Measuring feed rate: Feed rate for probing. If nothing is entered,
the measuring feed rate from the touch probe table is used. If
the entered measuring feed rate F is higher than the one in the
touch probe table, the feed rate is reduced to the value from the
touch probe table.

Q

Tool orientation: Orient the touch probe in the programmed
probing direction before each probing operation (machine-
dependent function)

P

PRINT outputs

0: OFF: Do not display measuring results

1: ON: Display measuring results

H

INPUT instead of measurement

0: Default: Obtain measured values by probing

1: PC test: Simulate probing cycle on the programming station

AN Log no.: Save measurement results in

"TNC:\table\messpro.mep" table (line numbers 0–99; the table
can be expanded if necessary)

Parameters

This manual is related to the following products: